问题描述

CP时间较长、因为在NSM模块更换期间两个磁盘上发生错误。

 [?]  Thu Mar 21 13:46:36 +0900 [node02: dsa_worker3: ses.status.etherConn.warn:error]: NS224NSM100 (S/N SHJSG2226000260) shelf 1 on channel 0x Ethernet connector warning for port e0a: a cable has been removed.  This element is on the rear of the shelf at the bottom, on module B.
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Unknown device e5a.01.2.19L9998: request failed after try #1: cdb 0x12. 
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Unknown device e5a.01.2.20L9998: request failed after try #1: cdb 0x12. 
 [?]  Thu Mar 21 13:46:43 +0900 [node02: disk_server_1: shm.threshold.agrsvIOCount:notice]: Disk e5b.01.1.19 has exceeded 12 IOs which have latencies greater than the threshold.
 [?]  Thu Mar 21 13:46:43 +0900 [node02: disk_server_0: shm.threshold.agrsvIOCount:notice]: Disk e5b.01.1.20 has exceeded 12 IOs which have latencies greater than the threshold.
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.19L0: request successful after retry #1/#0: cdb 0x9a:0000000077025300:0001:0040 (70052).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.19L0: request successful after retry #1/#0: cdb 0x9a:0000000077026300:0001:0040 (70047).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.19L0: request successful after retry #1/#0: cdb 0x9a:0000000077026ec0:0001:0040 (70044).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.20L0: request successful after retry #1/#0: cdb 0x9a:0000000077025300:0001:0040 (70054).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.20L0: request successful after retry #1/#0: cdb 0x9a:0000000077026300:0001:0040 (70048).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device e5b.01.1.20L0: request successful after retry #1/#0: cdb 0x9a:0000000077026ec0:0001:0040 (70046).
 [?]  Thu Mar 21 13:46:43 +0900 [node02: kernel: Nblade.NfsResponseTraceTriggerHourly:debug]: params: {'responseCount': '7941', 'trigger': '60'}
 [?]  Thu Mar 21 13:46:43 +0900 [node02: wafl_exempt10: wafl.cp.toolong:error]: Aggregate aggr_node02 experienced a long CP.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.