CONTP-426568:升级9.16.1后、使用QoS的iSCSI和FCP LUN/SUS可能无法访问
问题描述
- 升级ONTAP 9.16.1 iSCSI和FC SAN客户端后、在启用了QoS的LUN/SUS (在文件、LUN/SU、卷或SVM级别)上报告类似如下的错误消息:
2025-03-27T07:05:48.001Z cpu0:2107309) [HB state abcdef02 offset 3670016 gen 197 stampUS 23984552598485 uuid 6676affe-e695ad86-fb84-e6fdaca0003a jrnl <FB 33554432> drv 24.82 lockImpl 4 ip 10.13.2462025-03-27T07:05:48.426Z cpu49:2101136 opID=4b6b6c35)HBX: 3063: 'NETAPP_LUN1': HB at offset 3670016 - Waiting for timed out HB:
2025-03-27T07:05:48.426Z cpu49:2101136 opID=4b6b6c35) [HB state abcdef02 offset 3670016 gen 197 stampUS 23984552598485 uuid 6676c498-e695ad86-fb84-e6fdaca0affe jrnl <FB 33554432> drv 24.82 lockImpl2025-03-27T07:05:55.984Z cpu49:2107324)HBX: 3063: 'NETAPP_LUN1': HB at offset 3670016 - Waiting for timed out HB:
- 其症状可能包括:超时问题、无法访问LUN存储、VMFS数据存储库无响应以及ESXi主机无法识别LUN。