CONVA-82695:由于介质错误或已恢复的错误、系统发生中断
问题描述
- 此存储设备发生意外重新启动、并显示:WAFL hung for <aggregate name> 9.12.1。in SK Process WAFL上的<nn>
- 在重新启动之前、存储设备会报告与聚合关联的一个或多个驱动器出现介质错误。
- EMS报告:
5 月 26 日星期五 01:57:51 +0200 [NODE01:raidio_thread:raid_rg_readerr_repair_data_1:notice]:params:{'site':'Local','disk_rpm':'10000','vendor':'NETAPP','firmware_revision':'NA03','shelf':'51','disk_info':'磁盘/aggr_mmo_18sas_03/plex0/rg1/FC_switch_A_1:6.126L1040 Shelf 51 Bay 13 [NETAPP X343_SSKBE1T8A10 NA03] S/N [XXXXXXXX] UID [5000C500:D1818EB7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]','vbn':'9447206211','bay':'13','carrier':'','serialno':'XXXXXXXX','owner':'','model':'X343_SSKBE1T8A10','disk_type':'4','blockNum':'235420675'}
5 月 26 日星期五 01:57:52 +0200 [NODE01:disk_server_0:disk.ioReassignSuccess:notice]:磁盘 FC_switch_A_1:6.126L1040:扇区 1883365400 已重新分配(203)。磁盘FC_switch_A_1:6.126L440磁盘架51托架13 [XXXX033_SSKBE1T8A10 NetApp NA03] S/N [XXXXXXXXXXXX] UID [5000C500:D181818EB7:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000:000000000000000000000000]