跳转到主内容

CONAP-430498:由于PCIe链路初始化错误、A70无法访问NVMe磁盘

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

问题描述

  •  由于PCIe链路初始化错误、A70无法访问NVMe磁盘 

{}  [Node-02: SPR error: pcie.stealth.errors:debug]: params: {'pcie_errors': 'SPR:Socket1:IIO-Stack5:RPT(172,1,0): Microchip PCI-E Switch on Controller, Br[4068](174,15,0): DevStatus(Corr), CorrErr(Rcvr); '{}}
  [Node-02: kernel: nvme.link.error:error]: PCIe link initialization error for NVMe SSD in slot 7.
  [Node-02: scsi_cmdblk_strthr_admin: disk.timeout.flush.start:notice]: Aggressive timeout flush started on disk 0n.7 S/N XXXXXXXXXX. Details: Power Cycled: true Reason: Disk Spasm.
  [Node-02: scsi_cmdblk_strthr_admin: scsi.cmd.pastTimeToLive:error]: Disk device 0n.7L0: request failed after try #1: cdb 0xe2:01:0100000000000000:000000400000.
  [Node-02: config_thread: raid.disk.offline:notice]: Marking partner:Disk 0n.7 Shelf 0 Bay 7 [NETAPP   X4025S173A3T8NTE NA50] S/N [XXXXXXXXXX] UID [374A4130:58606713:00253854:00000002:00000000:00000000:00000000:00000000:00000000:00000000] offline.
  [Node-02: svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk ?.? (674A4130:58606713:00253854:00000002:500A0981:00000001:00000000:00000000:00000000:00000000) has recently changed or the node (Node-02) is missing the disk.
 
  • NVME disk is missed from sysconfig -a 

  6  :NetApp  X4025S173A3T8NTE NA50 3662.5GB 4160B/节(XXXXXXXX)==>缺少磁盘7
  8  :NetApp  X4025S173A3T8NTE NA50 3662.5GB 4160B/节(XXXXXXXX)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.