跳转到主内容

CONAP-403485:由于2n MetroCluster中的驱动器出现故障、导致节点崩溃和切换失败(AUSO)

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

问题描述

  • 单个磁盘上报告了SCSI.cmd错误、从而导致节点崩溃:

 [?]  Fri Feb 21 06:00:15 +0100 [Cluster1-01: slifc_intrd: scsi.cmd.checkCondition.bridge.SAS.event:debug]: Disk device switchA1:9.126L1524: Check Condition: CDB 0x2f:b8192800:0400: Sense Data SCSI:aborted command-  (0xb- 0x88 0x4 0x81)(2041).
 [?]  Fri Feb 21 06:00:17 +0100 [Cluster1-01: slifc_intrd: scsi.cmd.checkCondition.bridge.SAS.topoChange:debug]: Disk device switchA2:8.126L1524: Check Condition: CDB 0x2f:b8192000:0400: Sense Data SCSI:aborted command-  (0xb- 0x88 0x3 0x1)(4276).

[?]  Fri Feb 21 06:20:26 +0100 [Cluster1-01: drsom_watch: sk.panic:alert]: Panic String: DR DRSOM_SSTBL_OP_SWITCHOVER Operation is Hung in drdom_SO in SK process drsom_watch on release 9.13.1P9 (C)

  • 因此、AUSO (自动切换)失败、DR配对节点也崩溃: 

[?]  Fri Feb 21 06:52:37 +0100 [Cluster2-01: send_boot_msg_thread: mgr.stack.string:notice]: Panic string: DR DRSOM_SSTBL_OP_SWITCHOVER Operation is Hung in drdom_SO in SK process drsom_watch on release 9.13.1P9 (C)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.