CONTP-195074:间歇性收到False MissingPathFomSwitchToNSM_Alert
问题描述
- Receiving intermittent “MissingPathFromSwitchToNSM_Alert” from multiple shelves:
- Alerts clear immediately and are not persistant:
- Nodes never transition out of Quad Path HA during the timeframe of these alerts:
- There are no other indicators in the event logs that correlate with shelf errors during the timeframe of the alerts
- Review of the diagnostics shelf logs do not report any alerts or errors
- Review of the cabling and configuration from ONTAP side everything is cabled correctly and nodes reporting the correct cabling: Cable shelves as switch-attached storage - NS224 shelves