跳转到主内容

CONAP-118018:FAS2820可能会错误地在SAS适配器端口0d上显示错误消息

Views:
5
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

问题描述

  • FAS2820存储系统支持SAS适配器端口0a、0b和0c。
  • 它不支持适配器端口0d。
  • 可能会错误地发布类似于以下内容的消息。
    [Node01: pmcsas_timeout_0: sas.adapter.debug:debug]: params: {'adapterName': '0d', 'debug_string': 'Link down too long ... offlining'}
    [Node01: pmcsas_timeout_0: sas.link.error:debug]: Could not recover link on SAS adapter 0d after 45 seconds. Offlining the adapter.
    [Node01: pmcsas_asyncd_0: sas.adapter.debug:debug]: params:
    {'adapterName': '0d', 'debug_string': 'pmcsas_asyncd_offline'}


Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.