跳转到主内容

SQL完整性检查显示失败、vipmgr

Views:
26
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9
  • andu

问题描述

无法在ONTAP升级期间运行验证

RDB Replica Health Check

  Error   Error: Replicated database is malformed on node "node 1"
         in process "vifmgr". 
         Action: Contact technicalsupport for assistance.
 

Cluster::*> debug rdb sql integrity check show
Node        Process  Integrity
----------------- -------- -----------------
op3sacl01      bcomd   ok
             crs     ok
             mgwd    ok
             vifmgr  row 5 missing from index vs_routes_table_index
                 row 5 missing from index vifmgr_vs_routes_index
             vldb    ok
op3sacl02      bcomd   ok
             crs    ok
             mgwd    ok
             vifmgr  row 5 missing from index vs_routes_table_index
                   row 5 missing from index vifmgr_vs_routes_index
             vldb    ok

cluster::*> debug smdb table vs_routes_table show
vsid destination gateway   metric ipspaceid  routeUuid               uuid
---- ----------- ---------- ------ ---------- ------------------------------------ ------------------------------------
3   0.0.0.0/0   10.146.0.1 20    4294967295 3903bb6a-56a9-11ed-8ffc-d039ea910a3d 3903bb6a-56a9-11ed-8ffc-d039ea910a3d
4294967295 0.0.0.0/0 10.146.250.1 20 4294967295 ad4927f3-2867-11ed-8ffc-d039ea910a3d ad4927f3-2867-11ed-8ffc-d039ea910a3d
4294967295 10.122.51.0/24 10.146.51.1 20 4294967295 cc59d71d-4dd8-11ed-8ffc-d039ea910a3d cc59d71d-4dd8-11ed-8ffc-d039ea910a3d
4294967295 10.124.51.0/24 10.146.51.1 20 4294967295 183e750a-4dd9-11ed-8ffc-d039ea910a3d 183e750a-4dd9-11ed-8ffc-d039ea910a3d
4294967295 10.147.0.0/20 10.146.51.1 20 4294967295 04516ea7-6015-11ed-8ffc-d039ea910a3d 04516ea7-6015-11ed-8ffc-d039ea910a3d

Error: show failed: Loop detected in next() for table vs_routes_table. Next on "4294967295 10.147.0.0/20 10.146.51.1" returned "4294967295 10.147.0.0/23
    10.146.51.1".
5 entries were displayed.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.