跳转到主内容

为什么ONTAP 9.7和9.8之间的自动自适应数据压缩节省值不同?

Views:
6
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

  • AFF 系统
  • ONTAP 9.8
  • 温度敏感型存储效率(TSSE)

问题解答

  • ONTAP 9.7和ONTAP 9.8在自动自适应数据压缩节省量方面具有不同的值:

ONTAP 9.7:
cluster1::*> storage aggregate efficiency show -aggregate data_aggr1
               Aggregate: data_aggr1
                  Node: cluster1_node01
Has Auto Adaptive Compression Savings: false  

ONTAP 9.8:
cluster2::*> storage aggregate efficiency show -aggregate data_aggr2
               Aggregate: data_aggr2
                  Node: cluster2_node01
Has Auto Adaptive Compression Savings: true   
<<<TSSE已启用

  • TSSE是在ONTAP 9.8中推出的、并在新创建的精简配置AFF 卷上自动启用。
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.