是什么触发了 LIF 的自动还原流程?

Views:
37
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用于

ONTAP 9

问题解答

  • 群集 LIF 的自动还原要求主端口在尝试处理还原之前发送端口已启动的消息
  • 要使自动还原正常工作:
    • 必须将 LIF auto-revert的参数设置为"true"
    • 自动过程触发 LIF 的主端口,以发送端口再次打开的消息
      • LIF 的手动迁移和端口的手动上/下不会触发
    • LIF 的粘滞位设置为"false"
      • 粘滞位是手动迁移 LIF 时设置的 true/false 标志
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.