由于不一致,无法完成 " 卷移动 "
适用场景
- ONTAP 9
- 卷移动
问题描述
- 卷中的 WAFL 用户数据块不一致,导致卷移动操作无法执行
- 可能会出现如下错误:
raidio_thread: raid_cksum_bad_file_block_1:error]: params: {'disk_rpm': '7200', 'disk_type': '6', 'vendor': 'NETAPP ', 'level': '0', 'vol': 'vol1', 'shelf': '11', 'disk_info': 'Disk /aggr1/plex0/rg1/5a.11.17 Shelf 11 Bay 17 [NETAPP X308_SMEGA03TSSA NA02] S/N [Z1Y0T8QQ] UID [50000C90:0058F96C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '17', 'firmware_revision': 'NA02', 'carrier': '', 'bno': '48', 'snapid': '0', 'vol_type': 'volume', 'serialno': 'Z1Y0T8QQ', 'owner': '', 'model': 'X308_SMEGA03TSSA', 'fileid': '0', 'blockNum': '470779010', 'ino_type': ''}
repl_phys_read: repl.physdiff.invalid.hole:EMERGENCY]: Replication of volume 'vol1@vserver:d6872a4f-afcf-11e6-b675-00a09855e865' (DSID 1104) encountered an inconsistent block (VVBN 13616861496).
Mon Aug 23 16:13:39 0000 [node1: mgwd: mgmtgwd.jobmgr.jobcomplete.failure:info]: Job "Volume Move"[id 102744] (Move "vol1" in Vserver "svm1" to aggregate "aggr2") completed unsuccessfully: Replication encountered an inconsistent block at source. A file system inconsistency was detected replicating data from volume "cluster1://svm1/vol1". (1).