检测到不受支持的以太网交换机
适用场景
- ONTAP 9
- 集群网络交换机
问题描述
system health alert show
ReportsUnsupported Ethernet switch is detected
。
Node: NodeA
Resource: Swtich01
Severity: Major
Indication Time: Mon Jan 16 17:00:52 2023
Suppress: false
Acknowledge: false
Probable Cause: Unsupported Ethernet switch is detected.
Possible Effect: Communication problems and network connectivity issues
occur.
Corrective Actions: Unsupported Ethernet switch "Swtich01"
found. Connect a supported Ethernet switch to the
network.
system cluster-switch show
ReportsIP address not reachable
。
Cluster::*> system cluster-switch show
Switch Type Address Model
--------------------------- ------------------ ---------------- ---------------
Swtich01 cluster-network 192.168.x.x OTHER
Serial Number: Unknown
Is Monitored: false
Reason: IP address not reachable
Software Version: Cisco Nexus Operating System (NX-OS) Software, Version
9.3(5)
Version Source: CDP/ISDP