启动SVM DR后、MGWD服务将继续重新启动
- Views:
- 6
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-9
- Specialty:
- core<a>2008584398</a><a>翻译</a>
- Last Updated:
适用场景
ONTAP 9.3
问题描述
- 在启动SVM (Storage Virtual Machine)灾难恢复后、MGWD (管理网关)服务将继续重新启动。
- MGWD Panic字符串如下所示。
示例
[HostnameA: mgwd: ucore.panicString:error]:: 'mgwd: assertion ("CpsRdbMonitor failed to lock" == 0) at src/cps/cps_rdb_locking.cc:50 failed, raising SIGABRT(6) at RIP 0x81ab6aeda (pid 8243, uid 0, timestamp 1608113419)'
- 在配对节点上、MGWD服务也处于脱机状态。
示例
::> set advanced
HostnameB::*> cluster ring show
Node UnitName Epoch DB Epoch DB Trnxs Master Online
--------- -------- -------- -------- -------- --------- ---------
HostnameA mgmt 0 2130 88 - offline ***
HostnameA vldb 56 56 1 WPMPNASCL01A master
HostnameA vifmgr 55 55 46 WPMPNASCL01A master
......
HostnameB mgmt 0 2130 88 - offline ***
HostnameB vldb 56 56 1 WPMPNASCL01A secondary
HostnameB vifmgr 55 55 46 WPMPNASCL01A secondary
......