系统级诊断测试失败、并显示Unigen NVDIMM
适用场景
- ONTAP 9
- FAS8300/8700
- AF-A400
问题描述
- 系统级诊断测试失败 、并在首次尝试和第二次尝试测试成功时显示Unigen NVDIMM。
第一测试:
Memory:
dimm11 16 GB 3200 MT/s 1 Unigen
Diagnostics tool for FAS8300 - Version 07.01.04
Action Id How Name Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest: 1 Foreground MEM:patternverify:NVDIMM Running -------------
Error: no valid data- Slot 11
Error
第二次测试:
Diagnostics tool for FAS8300 - Version 07.01.04
Action Id How Name Status
---------- ---- ---------- ------------------------------------------- --------------------------------
RunTest: 1 Foreground MEM:patternstore:NVDIMM Running -------------
Success
- 在测试后和重新启动期间、系统检测到以下错误:
System will power cycle and wait NVDIMM backup
Running full memory initialization.
DIMM F0: NVDIMM in ERROR condition (status = 00000801).