跳转到主内容

删除单个磁盘架后、存储故障转移输出会显示HA节点之间的差异

Views:
40
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFA系统

问题描述

  • 在FAS或AFF系统中、 删除单个磁盘架时、storage failover show 在HA节点中显示的输出不同。
    • 从 节点01中的SAS端口0a、5b上拔下缆线时、它会显示:
      ::> storage failover show
                      Takeover 
      Node       Partner     Possible State Description  
      -------------- -------------- -------- -------------------------------------
      Node-01       Node-02       -     Kernel loaded
      Node-02       Node-01       false   In takeover
    • 从 节点-02中的SAS端口0c、5d上拔下缆线时、它会显示:
      ::> storage failover show
                      Takeover      
      Node       Partner     Possible State Description  
      -------------- -------------- -------- -------------------------------------
      Node-01     Node-02     false   Normal giveback not possible:
                          partner missing file system disks
      Node-02     Node-01     -     Waiting for giveback
  • 正常情况下的系统配置:
    • 节点01:
      • SYSCONFIG-A:

        slot 0: SAS Host Adapter 0a (Broadcom SAS3616W rev. 2, SAS, <UP>)
           ...
           01.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
           Shelf 1: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141
        slot 5: SAS Host Adapter 5b (Broadcom SAS3616W rev. 2, SAS, <UP>)
           ...
           01.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
           Shelf 1: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141

      •  STORAGE-FAILOVER.XML:

Node   Node-01
Partner Name   Node-02
Local Mailbox Disks   1.1.12.P3, 1.1.13.P3, 1.1.14.P3
Partner Mailbox Disks   1.1.0.P3, 1.1.1.P3, 1.1.2.P3

SYSCONFIG-R

聚合aggr0_Node-01 (联机、RAID-DP、快速置零)(块校验和)

  Plex /aggr0_Node-01/plex0 (online, normal, active, pool0)
   RAID group /aggr0_Node-01/plex0/rg0 (normal, block checksums)

    RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    ---------   ------     ------------- ---- ---- ---- ----- --------------   --------------
    dparity    0a.01.12P3   0a   1   12  SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    parity     5b.01.13P3   5b   1   13  SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    ...
    data      0a.01.22P3   0a   1   22  SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5b.01.23P3   5b   1   23  SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      0c.11.12P3   0c   11  12  SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5d.11.13P3   5d   11  13  SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    ...
    data      0c.11.20P3   0c   11  20  SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5d.11.21P3   5d   11  21  SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)

    • 节点-02:
      • SYSCONFIG-A:

        slot 0: SAS Host Adapter 0c (Broadcom SAS3616W rev. 2, SAS, <UP>)
           ...
           11.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
           Shelf 11: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141
        slot 5: SAS Host Adapter 5d (Broadcom SAS3616W rev. 2, SAS, <UP>)
           ...
           11.23: NETAPP   X371_S164A960ATE NA54 915.4GB 520B/sect (S5xxxxxxxxxx)
           Shelf 11: DS224-12  Firmware rev. IOM12B A: 0141  IOM12B B: 0141

      • STORAGE-FAILOVER.XML:

        Node   Node-02
        Partner Name   Node-01
        Local Mailbox Disks   1.1.0.P3, 1.1.1.P3, 1.1.2.P3
        Partner Mailbox Disks   1.1.12.P3, 1.1.13.P3, 1.1.14.P3

      • SYSCONFIG-R:

Aggregate aggr0_Node-02 (online, raid_dp, fast zeroed) (block checksums)
  Plex /aggr0_Node-02/plex0 (online, normal, active, pool0)
   RAID group /aggr0_Node-02/plex0/rg0 (normal, block checksums)

    RAID Disk   Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    ---------   ------     ------------- ---- ---- ---- ----- --------------   --------------
    dparity    0a.01.0P3   0a   1   0   SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    parity     5b.01.1P3   5b   1   1   SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    ...
    data      0a.01.10P3   0a   1   10  SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5b.01.11P3   5b   1   11  SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      0c.11.0P3   0c   11  0   SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5d.11.1P3   5d   11  1   SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    ...
    data      0c.11.8P3   0c   11  8   SA:B   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)
    data      5d.11.9P3   5d   11  9   SA:A   0   SSD   N/A 9594/19650048    9602/19666432 (fast zeroed)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.