系统健康警报中报告了不存在交换机的 ClusterSwitchConfig_Alert
适用场景
- ONTAP 9
- 集群交换机运行状况监控器(CSHM) AutoSupport消息
问题描述
- 交换机子系统健康状况下降:
cluster1::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster ok
- EMS 报告以下一个或多个健康警报:
[Node_01: cshmd: hm.alert.raised:alert]: Alert Id = SwitchUnreachable_Alert , Alerting Resource = SW1(FOCXXXXXXXX)
raised by monitor ethernet-switch
[Node_01
: cshmd: hm.alert.raised:alert]: Alert Id = ClusterSwitchConfig_Alert , Alerting Resource = node_01 raised by monitor cluster-switch
[Node_01
: cshmd: hm.alert.raised:alert]: Alert Id = SwitchCommunityString_Alert , Alerting Resource = SW1 raised by monitor cluster-switch
- 输出
system health alert show
类似地显示以下一项或多项内容:
Node: node-01
Alert ID: SwitchUnreachable_Alert
Resource: sw1
Probable Cause: The ethernet switch's IP address is not reachable from
the local node.
Possible Effect: Monitoring of the switch and log collection will not
function.
Corrective Actions: Ensure that the IP address is reachable or specify the
correct reachable IP address.
Node: node-01
Alert ID: ClusterSwitchConfig_Alert
Resource: node-01
Probable Cause: One or more nodes are not connected to both cluster
switches.
Possible Effect: If one cluster switch fails, "node0-1" might lose
access to the cluster.
Corrective Actions: Ensure the switch "sw1" is connected
to the node "node-01".
Node: node-01
Alert ID: SwitchCommunityString_Alert
Resource: sw1
Probable Cause: Cluster switch "sw1" with IP address
"123.123.123.123" is not reachable via SNMP. Incorrect
SNMP community string might be configured on the
cluster switch.
Possible Effect: Cluster switch communication problems and
accessibility issues.
Corrective Actions: Check the SNMP community string on the cluster switch
to verify the expected community string is configured.
Use the "system cluster-switch show -snmp-config"
command to view the expected community string.
- 警报中的交换机名称和 IP 地址不属于任何集群交换机,或在无交换机集群的情况下报告。EMS
- 命令
system switch ethernet show
为空白或未知,或报告切换IP address not reachable
。 - 删除运行状况警报不会解决问题描述问题。