适用场景

  • ONTAP 9
  • MCC IP

问题描述

  • 此节点已联机并提供数据、聚合托管在此节点上、但无法在集群中访问。
  • 命令"show MetroCluster check show -instance"可创建以下输出:

                Time of Check: 4/24/2023 08:47:25
         Name of the Component: nodes
         Result of the Check: warning
Additional Information/Recovery Steps: All checks could not be run as some nodes were not reachable. Check if the cluster peer is available.

         Time of Check: 4/24/2023 08:47:25
         Name of the Component: lifs
         Result of the Check: ok
Additional Information/Recovery Steps:

         Time of Check: 4/24/2023 08:47:25
         Name of the Component: config-replication
         Result of the Check: ok
Additional Information/Recovery Steps:

         Time of Check: 4/24/2023 08:47:25
         Name of the Component: aggregates
         Result of the Check: ok
Additional Information/Recovery Steps:

         Time of Check: 4/24/2023 08:47:25
         Name of the Component:clusters
         Result of the Check: ok
Additional Information/Recovery Steps:

         Time of Check:4/24/2023 08:47:25
         Name of the Component: connections
         Result of the Check: warning
Additional Information/Recovery Steps: The "ping" command terminated using the network addresses "10.0.0.4" and "10.0.0.3" on node "Node-02" in cluster "Cluster-01". Reason: Timeout: Operation "mccIpPingNetworkEndpoints_iterator::create_imp()" took longer than 25 seconds to complete [from mgwd on node "Node-01" (VSID: -3) to mgwd at 1.1.1.1]

         Time of Check: 4/24/2023 08:47:25
         Name of the Component: volumes
         Result of the Check: ok
Additional Information/Recovery Steps:

  • 此文件可能显示为已关闭
  • 通过CLI实施的命令可能会因超时错误而失败:

::> storage failover takeover -ofnode Node_n2 -option normal

Warning: Unable to list entries on node Node_n2. Timeout: Operation "software_image_iterator::next()" took longer than 25 seconds to complete [from mgwd on node "Node_N1" (VSID: -1) to mgwd at 169.254.12.1]

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.