在执行HeadSwap操作步骤期间执行部分根聚合
适用场景
AFF/FAS
问题描述
在headSwap操作步骤期间、根聚合在维护模式下显示为failed
Aggregate aggr0 (partial, raid_dp, partial) (block checksums)
Unassimilated aggr0 disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
orphaned 2b.10.0 2b 10 0 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
orphaned 2b.10.1 2b 10 1 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168
orphaned 2b.10.2 2b 10 2 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168