跳转到主内容

自加密驱动器出现故障后、ONTAP升级因错误而暂停

Views:
42
Visibility:
Public
Votes:
0
Category:
disk-drives<a>2010014339</a>
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9.  
  • 采用NVMe自加密驱动器(Self-Encryption Drive、SE)的AFF系统、包括但不限于:
    • X4014S173315TNTE
    • X4014S173A15TNTE
    • X4013S17337T6NTE
    • X4013WBORA7T6NTF

问题描述

  • 在ONTAP升级期间、一个或多个分区磁盘失败、并在启动期间显示以下错误:
[cluster-01:nse.op.failed:error]: Control failure on self-encrypting drive 0n.30; security provider: None, authority: None, during operation "tcg_tper_properties_sm".
[cluster-01:disk.init.failure.error:error]: Drive 0n.30 failed initialization due to error 5, sense code(5 2c 0 c).
[cluster-01:disk.init.failure.error:error]: Drive 0n.36 failed initialization due to error 5, sense code(5 2c 0 c).
[cluster-01:disk.init.failure.error:error]: Drive 0n.25 failed initialization due to error 5, sense code(5 2c 0 c).
[cluster-01:disk.init.failure.error:error]: Drive 0n.31 failed initialization due to error 5, sense code(5 2c 0 c).
[cluster-01:disk.init.failure.error:error]: Drive 0n.26 failed initialization due to error 5, sense code(5 2c 0 c).
[cluster-01:disk.init.failure.error:error]: Drive 0n.24 failed initialization due to error 5, sense code(5 2c 0 c).
  • 这可能会导致配对节点上的磁盘清单不匹配:
[cluster-01: svc_queue_thread: cf.disk.inventory.mismatch:error]: Status of the disk 0n.30P2 (xxxxxxxx:xxxxxxxx:xxxxxxxx:xxxxxxxx:xxxxxxxx:xxxxxxxx:00000000:00000000:00000000:00000000) has recently changed or the node (cluster-01) is missing the disk.
  • 配对节点可能会由于缺少磁盘而无法进行恢复:
[cluster-02: svc_queue_thread: cf.giveback.disk.check.fail:alert]: cf giveback failed: Partner is missing disks.
  • 由于网络结构池的原因、还可能会否决回送:
sfo.giveback.failed: Giveback of aggregate aggr1 failed due to destination check failed.
sfo.sendhome.subsystemAbort: The giveback operation of 'aggr1' was aborted by 'fabric pools'.
gb.netra.ca.check.failed: Giveback of aggregate 'aggr1' (uuid: xxxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx) failed due to Object store is not reachable on destination preventing object store access on the destination node.
  • 如果根聚合中的多个磁盘出现故障、则在启动时、节点可能会启动到:
Waiting for giveback...(Press Ctrl-C to abort wait)Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0
Entering FM state:5 because mbFound:0 local in headswap:0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.