交换机连接的存储警报错误
适用场景
- ONTAP 9
- NS224
- 交换机连接存储
问题描述
- SAS-connect运行状况报告已降级
::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect degraded
Environment ok
Memory ok
Service-Processor ok
Switch-Health degraded
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node ok
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
- 接收有关磁盘架布线和路径的持久运行状况警报
::> system health alert show -fields alert-id,subsystem,alerting-resource-name
node monitor alert-id alerting-resource subsystem alerting-resource-name
---------- --------------- ----------------------- ---------------------------- ---------- ----------------------------
netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-1 Switch-Health netapp-01-nvme1-1
netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-2 Switch-Health netapp-01-nvme1-2
netapp-01 ethernet-switch SwitchUnreachable_Alert netapp-01-nvme1-3 Switch-Health netapp-01-nvme1-3
netapp-01 node-connect NoPathToNSMB_Alert xxxxx SAS-connect Shelf 1.3
netapp-01 node-connect NoPathToNSMB_Alert xxxxx SAS-connect Shelf 1.2
netapp-02 node-connect SingleAdapterToShelf_Alert xxxxx SAS-connect Shelf 1.3
- 从ONTAP端查看布线和配置时、会显示所有布线均正确、节点会报告布线正确: 将缆线架作为交换机连接存储- NS224磁盘架