ONTAP 重新启动nphm后出错:CoredummpMissingAlert
适用场景
- AFF A700
- ONTAP 9
- NVMe核心转储设备(X9170A SSD)
问题描述
系统重新启动后、收到以下系统错误:
Health Monitor process nphm: CoredumpMissingAlert[-]) ALERT.
Probable Cause: Coredump device "Coredump" is missing from the system.
Possible Effect: Coredump files cannot be saved.
Corrective Actions:
1. Perform a takeover of this node and bring the node down for maintenance.
2. Verify that a coredump device is securely inserted in the system.
3. Use the "bye" LOADER command to reboot the node then perform a giveback.
检查运行状况警报和以下命令以验证:
Node2::*> system controller coredump-device show Size Device Node FRU/Display Name Vendor ID Device ID (GB) State Status ------------- -------------------- --------- --------- ------- --------- ------ Node1 Coredump 0 0 1024 warn unknown Node2 Coredump 0 0 1024 warn unknown 2 entries were displayed. Node2::*> debug smdb table nphm_coredump_info_view show serial-num vendor-id device-id display-name unique-name monitor health-status device-state size health shelf-status ---------- --------- --------- ------------ ----------- ---------- ------------- ------------ ---- ------- ------------ - 0 0 Coredump - controller not-present warn 1024 unknown present