跳转到主内容

在ONTAP集群映像验证期间出现错误:"未找到根卷记录"

Views:
17
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用场景

  • ONTAP 9
  • ONTAP升级

问题描述

  • 在ONTAP升级期间,命令 cluster image validate  返回错误:
 
Cluster ::> cluster image validate -version 9.XPXX
It can take several minutes to complete validation...
It can take several minutes to complete validation...

Error: show failed: Root volume record not found for nodes: Cluster-Node1.
Contact support personnel for assistance.
 
  • 命令ring show 显示 以下内容 

Cluster::*> ring show
  (cluster ring show)
Node    UnitName Epoch   DB Epoch DB Trnxs Master   Online
--------- -------- -------- -------- -------- --------- ---------

Error: rdb_ring_info: RDB ring state query of 127.0.0.1 for vldb failed on RPC connect: clnttcp_create: RPC: Remote system error - Connection refused
    rdb_ring_info: RDB ring state query of 127.0.0.1 for vifmgr failed on RPC connect: clnttcp_create: RPC: Remote system error - Connection refused
    rdb_ring_info: RDB ring state query of 127.0.0.1 for bcomd failed on RPC connect: clnttcp_create: RPC: Remote system error - Connection refused
    rdb_ring_info: RDB ring state query of 127.0.0.1 for crs failed on RPC connect: clnttcp_create: RPC: Remote system error - Connection refused
Node1
      mgmt    16611   16611   120941   Node2
                             secondary
Node1
      vldb    -     -     -     -      -
Node1
      vifmgr   -     -     -     -      -
Node1
      bcomd   -     -     -     -      -
Node1
      crs    -     -     -     -      -
Node2
      mgmt    16611   16611   120941   Node2
                             master
Node2
      vldb    26     26     1     Node2
                             master
Node2
      vifmgr   27     27     27     Node2
                             master
Node2
      bcomd   16700   16700   6     Node2
                             master
Node2
      crs    26     26     1     Node2
                             master
10 entries were displayed.

  •  在命令中列出了节点1的RPC连接错误 port show

Cluster::*> port show

Warning: Unable to list entries for vifmgr on node "Node1": RPC: Couldn't make connection [from mgwd on node "Node2" (VSID: -1) to vifmgr at 169.254.20.11].

Node: Node2
                                    Ignore
                          Speed(Mbps) Health   Health
Port    IPspace    Broadcast Domain Link MTU  Admin/Oper  Status   Status
--------- ------------ ---------------- ---- ---- ----------- -------- ------
e0M     Default    10.128.10.0/24   up   1500  auto/1000  healthy  false
e0a     Cluster    Cluster      up   9000 10000/10000 healthy  false
e0b     Cluster    Cluster      up   9000 10000/10000 healthy  false
e0c     Default    10.128.50.0/24   up   1500  auto/10000 healthy  false
e0d     Default    10.128.50.0/24   up   1500  auto/10000 healthy  false
5 entries were displayed.

  • 命令sto fa show 显示以下内容:
 
Cluster::*> sto fa show
  (storage failover show)
                Takeover
Node       Partner     Possible State Description
-------------- -------------- -------- -------------------------------------
Node1      Node2      true    Connected to Node2. Waiting
                    for cluster applications to come
                    online on the local node. Offline
                    applications: vldb, vifmgr, bcomd,
                    crs, scsi blade, clam.
Node2      Node1      true    Connected to Node1, Partial
                    giveback
2 entries were displayed.


 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.