由于聚合上运行后台重复数据删除,禁用 TSSE 持续失败
适用于
- ONTAP 9.8 +
- AFF
- 温度敏感型存储效率(TSSE)
问题
在执行禁用 TSSE 在 FlexGroup 或 FlexVol 上的步骤时无法完成。
- 在以下示例中,FlexGroup 成员 0005 和 0009 失败。
Cluster::*> volume efficiency modify -compression true -compression-type adaptive -application-io-size 8k -vserver svm1 -volume FlexGroup
[Job 38752] Steps completed: 7 of 10.
Error: command failed: [Job 38752] Job failed: Failed to modify efficiency configuration for volume "FlexGroup" of Vserver "svm1": The following constituents failed to have efficiency changes applied: 5,9. The error was the same for all constituents, and was "Failed to set compression type and application I/O size on the volume. Switching between compression type or application I/O size is allowed only after undoing the compression savings on the volume.".
- EMS 日志报告错误事件如下:
Tue Nov 21 10:21:44 -0800 [node-01: f: sis.undo.aborted:error]: SIS undo operation for '/vol/FlexGroup__0005@vserver:777cf27d-d075-11ec-8cd0-d039ea3b58dd' has aborted: 'Undo or revert operation cannot be done since background deduplication is running on volume or aggregate. Wait for it to complete and then retry this command.'.volume efficiency show命令输出还显示与"Last Operation Error: Undo or revert operation cannot be done since background deduplication is running on volume or aggregate. Wait for it to complete and then retry this command."相同的消息