问题

  • 报告了意外的故障转移事件。
  • 接管确认为已完成。
  • 对于与接管中的系统的一些接口,数据服务被中断。
  • 只有在执行引导和关闭节点的回馈后,才会恢复数据服务。
  • 受影响节点的 EMS 日志(回馈后)显示以下与 Broadcast Domains 和故障转移目标可用性相关的消息:

Thu Oct 12 01:06:46 +0200 [Cluster-01-01: vifmgr: vifmgr.lifdown.noports:alert]: LIF lnode_01-lif_01 (on virtual server 6), IP address 123.123.123.123, currently cannot be hosted on node Cluster-01-01, port a0a-1716, or any of its failover targets, and is being marked as down.

...

Thu Oct 12 01:07:15 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.ok:notice]: Network port a0a-1716 on node Cluster-01-01 can reach its expected broadcast domain Cluster-01_ipspace-1716:__NFS_VLAN_1716_node1. No other broadcast domains appear to be reachable from this port.

Thu Oct 12 01:07:15 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.miscfg:error]: Network port a0b-1716 on node Cluster-01-01 cannot reach its expected broadcast domain Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster, but reachability was detected to broadcast domain Cluster-01_ipspace-1716:__NFS_VLAN_1716_node1.

...

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.multireach:error]: Network port a0a-1716 on node Cluster-01-01 can reach the following broadcast domains: Cluster-01_ipspace-1716:__NFS_VLAN_1716_node2,Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster.

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.ok:notice]: Network port a0a-1800 on node Cluster-01-01 can reach its expected broadcast domain Default:Default-5. No other broadcast domains appear to be reachable from this port.

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.multireach:error]: Network port a0b-1716 on node Cluster-01-01 can reach the following broadcast domains: Cluster-01_ipspace-1716:__NFS_VLAN_1716_node2,Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.