问题描述

  • 报告意外故障转移事件。
  • 接管已确认为已完成。
  • 与要接管的系统的某些接口的数据服务已中断。
  • 只有在启动并交还已关闭节点后、数据服务才会还原。
  • 受影响节点的EMS日志(在恢复之后)显示以下与广播域和故障转移目标可用性相关的消息:

Thu Oct 12 01:06:46 +0200 [Cluster-01-01: vifmgr: vifmgr.lifdown.noports:alert]: LIF lnode_01-lif_01 (on virtual server 6), IP address 123.123.123.123, currently cannot be hosted on node Cluster-01-01, port a0a-1716, or any of its failover targets, and is being marked as down.

...

Thu Oct 12 01:07:15 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.ok:notice]: Network port a0a-1716 on node Cluster-01-01 can reach its expected broadcast domain Cluster-01_ipspace-1716:__NFS_VLAN_1716_node1. No other broadcast domains appear to be reachable from this port.

Thu Oct 12 01:07:15 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.miscfg:error]: Network port a0b-1716 on node Cluster-01-01 cannot reach its expected broadcast domain Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster, but reachability was detected to broadcast domain Cluster-01_ipspace-1716:__NFS_VLAN_1716_node1.

...

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.multireach:error]: Network port a0a-1716 on node Cluster-01-01 can reach the following broadcast domains: Cluster-01_ipspace-1716:__NFS_VLAN_1716_node2,Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster.

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.ok:notice]: Network port a0a-1800 on node Cluster-01-01 can reach its expected broadcast domain Default:Default-5. No other broadcast domains appear to be reachable from this port.

Thu Oct 12 01:07:29 +0200 [Cluster-01-01: vifmgr: vifmgr.reach.multireach:error]: Network port a0b-1716 on node Cluster-01-01 can reach the following broadcast domains: Cluster-01_ipspace-1716:__NFS_VLAN_1716_node2,Cluster-01_ipspace_1716_intercluster:Cluster-01_broadcast_domain_1716_intercluster.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.