适用场景
ONTAP 9.12.1P2
FS424-12磁盘架
IOM12F
问题描述
- 在ONTAP升级到9.12.1P2后、FS424C磁盘架上出现磁盘架模块错误:"在模块中检测到严重错误"。
Cluster::*> storage shelf show -connectivity -shelf *
Errors:
------
Critical error detected in module "A".
Critical error detected in module "B".
- ONTAP未轮询并显示控制器机箱环境信息。因此、这会导致不会触发EMS事件、并且磁盘架维护请求(例如、磁盘架日志检索)失败。
Node-01*> disk_shelf db_list
Controller: B
Shelf| Shelf | Shelf|Shelf|Mstr|Gen Code| |Last| Poll (ms)
Handle| Type | State| Id | Mod| (Mask) | RA Handles |Poll| (min,max)
------+-------+------+-----+----+--------+------------------+----+----------
20000| IOM12F| OK| 0| 1 | 2(3) | 00181fe7 | N/A| 0, 0
Shelf| Page 0
Handle| STD , VU
------+----------
20000| 0000,0000
--------------------------------------------------------------------
Total Shelves: 1
--------------------------------------------------------------------
Node-02*> disk_shelf db_list
Controller: A
Shelf| Shelf | Shelf|Shelf|Mstr|Gen Code| |Last| Poll (ms)
Handle| Type | State| Id | Mod| (Mask) | RA Handles |Poll| (min,max)
------+-------+------+-----+----+--------+------------------+----+----------
20000| IOM12F| OK| 0| 0 | 2(1) | 00181fe7 | N/A| 0, 0
Shelf| Page 0
Handle| STD , VU
------+----------
20000| 0000,0000
--------------------------------------------------------------------
Total Shelves: 1
--------------------------------------------------------------------