ONTAP升级或重新启动后集群端口关闭
适用场景
- ONTAP 9
- 自动化无中断升级(ANDU)
问题描述
- ONTAP升级或重新启动后、集群端口显示为关闭。
storage failover show
显示以下状态问题描述。
Connected to Node01. Waiting for cluster applications to come online on the local node.
Offline applications: mgmt, vldb, vifmgr, bcomd, crs.
Takeover is not possible: The version of software running on each node of the SFO pair is incompatible, NVRAM log not synchronized
cluster image show-update-progress
显示Update Phase
为paused-on-error
、并且两个节点均未处于已连接和failed
状态。
Cluster::*> cluster image show-update-progress
Estimated Elapsed
Update Phase Status Duration Duration
-------------------- ----------------- --------------- ---------------
Pre-update checks completed 00:10:00 00:01:04
Data ONTAP updates paused-on-error 01:32:00 1 days 02:39
Details:
Node name Status Status Description
-------------------- ----------------- --------------------------------------
node01 waiting
node02 failed Error: Node "node02" is not in
"connected" state after giveback.
Action: Use the "storage failover
show" command to verify that node
"node02" is in the "connected"
state.
5 entries were displayed.
Status: Paused - An error occurred in "Data ONTAP updates" phase. The update cannot continue until the error has been resolved. Resolve all issues, then use the "cluster image resume-update" command to resume the update.