跳转到主内容

是否可以使用通配符在ONTAP 中的SVM-DR目标卷上禁用卷效率?

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core<a>2009214292.</a>
Last Updated:

适用场景

  • ONTAP 9.9.1

问题解答

在ONTAP 9.9.1中 override -command 、将失败、并显示以下错误:

::> set diag

::*> vserverconfig override -command "volume efficiency off -vserver de*ts* -volume sou*"

Error: command failed on vserver "destsvm" volume "source1": This operation is not permitted on a Vserver that is configured as the destination for identity preserve Vserver DR.

追加信息

先前的ONTAP 版本允许使用通配符。
 
ONTAP 9.7:
::*> vserver config override -command "volume efficiency off -vserver des*tsvm* -volume sou*" Efficiency for volume "source1" of Vserver "destsvm" is disabled. Efficiency for volume "source2" of Vserver "destsvm" is disabled. Efficiency for volume "source3" of Vserver "destsvm" is disabled. 3 entries were acted on.
  • 我们的开发团队目前正在对9.9.1和9.7之间的代码进行比较

Please contact NetApp Technical Support or log into the NetApp Support Site to create a case. Reference this article for further assistance.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.