跳转到主内容

升级前检查期间的 CPU 和 SAN 兼容性警告

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

适用于

  • ONTAP 9
  • FAS、AFF 系统
  • 为 SAN/NVMe 协议访问配置的集群

问题

在 ONTAP 升级期间,在更新前检查中观察到以下警告:

::*> cluster image show-update-progress

Update Phase   Status    Estimated Duration   Elapsed Duration
-------------------------------------------------------------------
Pre-update checks completed 00:02:00        00:01:18

Details:
Pre-update Check      Status   Error-Action
--------------------------------------------------------------
CPU Utilization      Warning   Warning: CPU utilization is high on nodes: NODE1.
                  Action: Before updating a node, verify that no node in the cluster is above 50% CPU utilization.
                  Use the command "node run -node <nodenames> -command sysstat -c 103" to view the CPU utilization of nodes.
SAN compatibility check  Warning   Warning: This cluster is configured for SAN or NVMe protocol access.
                  Confirm that the configuration is fully supported.
                  Action: Refer to the NetApp Interoperability Matrix Tool for interoperability information.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?