由于 FSINFO 块无效,聚合离线
适用于
- ONTAP 9
- FAS/AFF
问题描述
- 数据聚合(例如:Node_02_SAS_1)已脱机,无法联机。尝试在线聚合失败,出现以下错误:
Node-01-02::> aggr online -aggregate Node_02_SAS_1 Error: command failed: Failed to bring aggregate "Node_02_SAS_1" online. Reason: Neither fsinfoblock of aggregate 'Node_02_SAS_1' is valid.
- 聚合状态显示脱机:
Aggregate Size Available Used% State #Vols Nodes RAID Status --------------------------------------------------------------------------------------------- Node_01_SAS_1 11.39TB 3.30TB 71% online 357 Node-01 raid_dp, normal Node_02_SAS_1 0B 0B 0% offline 0 Node-02 raid_dp, normal
- 其他 EMS 日志消息:
wafl.volinfo.fsinfo.error: alert]: Bad Volinfo/Fsinfo magic for aggregateraid.config.online.req.invalid: notice]: Neither volume information block of Aggregate Node_02_SAS_1 is valid.