andu已在LOADER与HA配对节点暂停
适用场景
- ONTAP 9
- FAS 系列
- 2500系列
- 2600系列
- 2700系列
- FAS8200
- FAS8300/8700
- FAS9000
- AFF A系列
- A200
- A220/C190
- A300
- A320
- A400
- a700
- A700s
- A800
问题描述
- 在从ONTAP 9.7或更高版本自动无中断升级(ANDU)期间、升级暂停、并显示错误:
Thu Oct 06 23:05:56 +0000 [node-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "node-01": Error: {Node "node-02" is not in "waiting for giveback" state.}, Action: {Use the "storage failover show" to verify that node "node-02" is in one of the following states: "waiting for giveback" or "connected".}.
Thu Oct 06 23:05:56 +0000 [node-01: svc_queue_thread: callhome.andu.pausederr:alert]: params: {'epoch': '', 'subject': 'AUTOMATED NDU PAUSED'}
- 检查HA配对节点后、它无法自动启动、并显示
LOADER>
提示符。 - 修改映像后、控制台日志将显示暂停:
Setting default boot image to image1...
done.
Uptime: 91d6h35m30s
HALT: HA partner has taken over (ic) on Wed Apr 26 16:25:08 PDT 2023
Uptime: 91d6h35m43s
System halting...
- SP日志不会显示任何硬件错误、也不会显示正在进行的任何系统固件或BIOS更新。
SP> events all
SP> system log