ANDU失败、报告由于端口可访问程度问题描述而导致无法迁移数据LIP
适用场景
- ONTAP 9
- 自动无中断升级(ANDU)
问题描述
- ANDU暂停报告以下错误:
[node-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Node "node-02": Error: {Failed to migrate data LIFs from node"node-01".}, Action: {Migrate all of the data LIFs using the "network interface migrate-all -node node-01" command- 运行
network interface migrate-all -node node-01不会更正故障。 - 可访问测试显示端口未处于
ok状态。
cluster1::> network port reachability show -port e0M -detail -node *
Node Port Expected Reachability Reachability Status
------------ -------- ---------------------------- --------------------------
node1
e0M Default:Default multi-domain-reachability
Actual Reachability: Default:Default, Default:Default-1
Unreachable Ports: -
Unexpected Ports: node2:e0M
node2
e0M Default:Default-1 misconfigured-reachability
Actual Reachability: Default:Default
Unreachable Ports: -
Unexpected Ports: node1:e0M, node1:e3a, node2:e3a
2 entries were displayed.