CONAP-411813:Givback后、从非本地数据LIFs进行的客户端数据访问失败
问题描述
- 完成"storage Failover c归还"后、"ofnode "会在vreport中报告"Blade UUUI"的"聚合 差异"
- vreport的区别在于、WAFL报告了"frodne" dblade UUID、而VLDB错误地报告了在恢复操作期间重新定位的SFo聚合的"ofnode dblade UUUE"。示例:
::*> debug vreport show
aggregate Differences:
Name Reason Attributes
-------- ------- ---------------------------------------------------
aggr1 Present both in VLDB and WAFL with differences
Node Name: node-01
Aggregate UUID: c88f874f-9237-4ad9-a0f0-ecd0cb492d96
Aggregate State: online
Aggregate Raid Status: raid_dp, mirrored
Aggregate HA Policy: sfo
Is Aggregate Root: false
Aggregate Vol Count: 130
Is Composite Aggregate: false
Differing Attribute: Blade UUID
WAFL Value: a32cf117-8251-11eb-a586-d039ea450084
VLDB Value: d483d5e0-8250-11eb-a5eb-d039ea45008b - 对于该聚合上托管的受影响卷、vreport还可能报告"接合差异"。示例:
Name Reason Attributes
-------- ------- ---------------------------------------------------
mySVM:myVol File Handle for the Parent Volume does not match with Dblade
Parent Info:
VolName: myVol
MSID: 2147484730 DSID: 6583 vsID: 19
Child:
VolName: myVol
MSID: 0 DSID: 6565 vsID: 19 - Givback后、对"froune"上托管的"LIF"的客户端数据访问失败、除非将其迁移到"ofnode "
- 如果在"ofno"处于接管状态时进行了配置更改、则在恢复后、"ofno"的管理平台可能仍无法识别这些更改、从而导致在恢复后、"ofno"上的本地操作出现意外行为