问题描述

-andu验证失败并显示错误:
cluster image show-update-Progress
估计持续时间:00:10:00
已用持续时间:00:00:57
整体状态:集群Cluster1上的更新前检查失败。
在集群Cluster2上完成更新前检查。
群集名称:群集1状态:已完成
更新前检查状态错误操作-------------------------------

初始卷出现错误:此集群中有一个或多个
启用了回写检查选项的FlexCache回写FlexCache卷指向
初始卷

操作:使用"Data FlexCache原点
show-caches"列出所有
已启用回写选项并指向此集群中的原始节点的
flexaches
。在缓存集群中使用"vserver FlexCache config修改
-is-writback-enabled false -vserver
<cache_vserver>*"命令
禁用所有这些缓存上的回写
选项
、请等待几分钟、然后重试。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.