跳转到主内容

CONTP-221384:拔下交换机上的ISL后、未发出SNMP警报。

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
CORE
Last Updated:

问题描述

拔下ISL后,ONTAP中会生成以下警报,但不会发出SNMP警报:
FR11BST1::> event log show
time Node严重性事件-------------------------------

2024/2-024 06:48:03 FR11BST1-1 alAlert hm.alter.raised:警报ID = SwitchIslIfDownWarn_Alert,警报资源= FR1-1B11-S-9336-01 (FLM264202JJJ)/Ethernet1/15由监控器以太网交换机引发重新连接后,ONTAP中将收到hm.alter.Cleared,
并发出警报。
notiyd日志中出现以下错误:
Tue Mar 12 2024 08:07:15 +00:00 [kern_notiyd:info:2372] 0x80a47a200:0:错误:ems:::SNMP_handler:Unable to send the event to mgwd。原因:事件大小大于允许的最大缓冲区大小(即2016)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.