跳转到主内容

由于电池传感器无法读取、节点关闭

Views:
6
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>2009804163</a>
Last Updated:

适用场景

  • FAS26XX
  • ONTAP 9

问题描述

  • 节点会突然执行环境关闭。EMS日志中会显示以下内容:

Oct 14 15:19:34 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Curr' unreadable) CRITICAL.
Oct 14 15:19:34 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Curr' unreadable) CRITICAL.
Oct 14 15:19:34 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Initial FCC' unreadable) CRITICAL.
Oct 14 15:19:37 [Cluster1:nvmem.battery.packInvalid:EMERGENCY]: The incorrect NVMEM battery is installed. Expected part number is 271-00045. To prevent data loss, the system will shut down in 5 minutes.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Volt' unreadable) CRITICAL.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Full Cap' unreadable) CRITICAL.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge Volt' unreadable) CRITICAL.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dstg Cycles' unreadable) CRITICAL.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Dcharge FET' unreadable) CRITICAL.
Oct 14 15:20:27 [Cluster1:callhome.battery.failure:EMERGENCY]: Call home for BATTERY ('Bat Charge FET' unreadable) CRITICAL.
Oct 14 15:23:34 [Cluster1:monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery current critical)

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.