跳转到主内容

由于 FAS2552上的OPS面板故障、HA对无法启动

Views:
14
Visibility:
Public
Votes:
0
Category:
data-ontap-8
Specialty:
hw<a>2009717457</a>
Last Updated:

适用场景

  • FAS2552
  • DS2246
  • ONTAP 8.2.3 7-模式

问题描述

  • 前面板上的琥珀色指示灯亮起、磁盘架ID显示为8.8、所有硬盘驱动器上的指示灯均不亮。
  • 可以访问SP、但控制台上没有显示屏幕。
  • 打开两个节点上的电源故障。 
  • 两个节点上的2个PSU均处于缺失状态。

示例:

Record 819: Thu Jan  1 00:00:32 1970 [IPMI.notice]: 6902 | c0 | OEM: ffff7000ff00 | ManufId: 150300 | SP Power Reset
Record 820: Thu Jan  1 00:00:32 1970 [IPMI.notice]: 6a02 | c0 | OEM: fcff70560000 | ManufId: 150300 | POS Register: Power on Reset(Normal Power Cycle)
Record 821: Thu Jan  1 00:00:34 1970 [IPMI.notice]: 6b02 | 02 | EVT: 0301ffff | AC_Power_Fail | Assertion Event, "State Asserted"
Record 822: Thu Jan  1 00:00:34 1970 [IPMI.notice]: 6c02 | 02 | EVT: 0301ffff | Controller_Fault | Assertion Event, "State Asserted"
Record 823: Thu Jan  1 00:00:35 1970 [IPMI.notice]: 6d02 | 02 | EVT: 0150008b | Bat_1.5V | Assertion Event, "Lower Non-critical going low "
Record 824: Thu Jan  1 00:00:35 1970 [IPMI.notice]: 6e02 | 02 | EVT: 01520084 | Bat_1.5V | Assertion Event, "Lower Critical going low "
Record 825: Thu Jan  1 00:00:43 1970 [IPMI.notice]: 6f02 | 02 | EVT: 6f01ffff | PSU1_Present | Assertion Event, "Absent"
Record 826: Thu Jan  1 00:00:43 1970 [IPMI.notice]: 7002 | 02 | EVT: 6f01ffff | PSU2_Present | Assertion Event, "Absent"

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.