跳转到主内容

由于 DS460-12 磁盘架上的多个磁盘丢失而导致接管

Views:
16
Visibility:
Public
Votes:
0
Category:
disk-shelves
Specialty:
hw
Last Updated:

适用场景

DS460-12 磁盘架

问题描述

  • 系统上发生计划外接管。
  • 观察到的 EMS 消息:

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.24: Adapter/target error: HA status 0x7: cdb 0x88:000000014b839560:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0b.02.27: Adapter/target error: HA status 0x7: cdb 0x88:0000000160a47b68:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.30: Adapter/target error: HA status 0x7: cdb 0x88:000000013ba25ec8:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.33: Adapter/target error: HA status 0x7: cdb 0x88:0000000123ae7078:00000008. Targeted device did not respond to requested I/O. I/O will be retried.

config_thread: cf.multidisk.fatalProblem:info]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr02_SATA_01: raid volfsm, fatal multi-disk error.. Raid type - raid_dp Group name plex0/rg0 state NORMAL. 4 disks failed in the group. Disk 0a.02.24 Shelf 2 Drawer 3 Slot 0 Bay 24 [NETAPP X375_SMBPE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.27 Shelf 2 Drawer 3 Slot 3 Bay 27 [NETAPP X375_SMBPE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.30 Shelf 2 Drawer 3 Slot 6 Bay 30 [NETAPP X375_WVELE04TA07 NA00] S/N [XXXXXXXX] UID [XXXXXXX:XXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk /aggr02_SATA_01/plex0/rg0/0a.02.33 Shelf 2 Drawer 3 Slot 9 Bay 33.

  • 聚合保持脱机状态:
     Aggregate aggr02_SATA_01 (failed, raid_dp, partial) (block checksums) Plex /aggr02_SATA_01/plex0 (offline, failed, inactive) RAID group /aggr02_SATA_01/plex0/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity 0b.02.0 0b 2 0 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 parity 0a.02.3 0a 2 3 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.6 0b 2 6 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.9 0a 2 9 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.12 0b 2 12 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.15 0a 2 15 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.18 0b 2 18 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.21 0a 2 21 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data FAILED N/A 3807816/ - data 0b.02.36 0b 2 36 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.39 0a 2 39 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.42 0b 2 42 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.45 0a 2 45 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.48 0b 2 48 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0a.02.51 0a 2 51 SA:B 0 FSAS 7200 3807816/7798408704 3815447/7814037168 data 0b.02.54 0b 2 54 SA:A 0 FSAS 7200 3807816/7798408704 3815447/7814037168 Raid group is missing 4 disks.
  • 磁盘架已打开电源,但安装驱动器的抽屉上不会发生 LED 活动。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.