扩展器 0 : 11a222 : 333333b : cc 上的一个或多个( 1 ) PHY 处于错误状态
适用场景
- FAS/AFA系统
- 磁盘驱动器
问题描述
- 扩展器上的物理处于错误状态、对于两个SAS路径。示例:
sas.adapter.debug: adapterName="2", debug_string="One or more (1) PHYs on expander 0:11a222:333333b:dd are in a bad state."
sas.adapter.debug: adapterName="7", debug_string="One or more (1) PHYs on expander 0:11a222:444444c:ee are in a bad state."
Unknown
通过两个SAS路径显示与磁盘相关的一个物理的""状态。示例:
::> storage shelf show -instance
Shelf Name: 5.22
Stack ID: 5
Shelf ID: 22
Shelf UID: 00:11:22:33:44:55:66:77
Serial Number: SHU0123456A7B8C
Module Type: IOM6
Model: DS4246
Shelf Vendor: NETAPP
Disk Count: 24
Connection Type: SAS
Shelf State: Online
Status: Normal
SAS Ports:
-- Port Speeds Gb/s -- Power Port
Phy # IOM Port Type WWPN Operational Negotiated Status Status
----- --- --------- ----------------- ----------- ---------- ------ -----------
...
29 A Disk 50000c90000948cd 6.0 6.0 on Enabled
30 A Disk - - - - Unknown
31 A Disk 50000c9000095b3d 6.0 6.0 on Enabled
...
29 B Disk 50000c90000948ce 6.0 6.0 on Enabled
30 B Disk - - - - Unknown
31 B Disk 50000c9000095b3e 6.0 6.0 on Enabled
...
Rate Uknown
该托架磁盘的""状态。示例:
::> system node run -node node_name sasstat expander_phy_state 2b.22
...
Pwr
Pwr Ccl Rsv Rls
PHY/BAY STATE ON Cnt Cnt Cnt
... ... ... ... ... ...
30/22 Rate Uknown YES 13 0 0
- 磁盘架中的其他磁盘不报告任何问题描述。