跳转到主内容

在DQP文件更新期间显示虚假的肯定备件不足消息

Views:
6
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009年145682</a><a>、用于翻译</a>
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • 动态驱动器识别(DDR)

问题描述

  • 在DQP文件更新期间、ONTAP 会触发"spares low" AutoSupport 消息。
  • EMS日志显示正在进行DDR扫描的磁盘未正确检测到、并且在raid.disk.insertedDDR扫描之后是新出现的""信息。

[?] Thu Apr 21 15:54:48 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 2d.13.11 Shelf 13 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [31N0A0B4F9XC] UID [5000039A:C859DC2C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:48 +0900 [node-1: raidio_thread: raid_spares_media_scrub_suspend_1:notice]: params: {'model': 'X336_TTCRE04TA07', 'vendor': 'NETAPP  ', 'disk_rpm': '7200', 'firmware_revision': 'NA04', 'shelf': '1', 'disk_info': 'Disk 0a.01.11 Shelf 1 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '11', 'carrier': '', 'serialno': 'XXXXXXXXXXXX', 'owner': '', 'percentage': '68', 'disk_type': '8', 'blockNum': '659674624'}
[?] Thu Apr 21 15:54:48 +0900 [node-1: raidio_thread: raid_spares_media_scrub_suspend_1:notice]: params: {'model': 'X336_TTCRE04TA07', 'vendor': 'NETAPP  ', 'disk_rpm': '7200', 'firmware_revision': 'NA04', 'shelf': '3', 'disk_info': 'Disk 2b.03.10 Shelf 3 Bay 10 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '10', 'carrier': '', 'serialno': 'XXXXXXXXXXXX', 'owner': '', 'percentage': '68', 'disk_type': '8', 'blockNum': '659564288'}
[?] Thu Apr 21 15:54:48 +0900 [node-1: raidio_thread: raid_spares_media_scrub_suspend_1:notice]: params: {'model': 'X336_TTCRE04TA07', 'vendor': 'NETAPP  ', 'disk_rpm': '7200', 'firmware_revision': 'NA04', 'shelf': '3', 'disk_info': 'Disk 2b.03.11 Shelf 3 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Local', 'bay': '11', 'carrier': '', 'serialno': 'XXXXXXXXXXXX', 'owner': '', 'percentage': '68', 'disk_type': '8', 'blockNum': '659569152'}
[?] Thu Apr 21 15:54:49 +0900 [node-1: bg_disk_ddr_scanner_admin: disk.ddr.scan.summary:debug]: DDR Scan has completed. (132 label reads, 36 label writes, 0 unreadable, 0 unqual, 0 cb qual, 0 label qual, 72 dqp update, 36 label match, 0 reset match, 0 mis-sized, 72 reset, 0 skipped - 133 preempts )
[?] Thu Apr 21 15:54:49 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 0a.01.10 Shelf 1 Bay 10 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 0a.01.11 Shelf 1 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 2b.02.10 Shelf 2 Bay 10 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 2b.02.11 Shelf 2 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 2b.03.10 Shelf 3 Bay 10 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [XXXXXXXX:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: dmgr_thread: raid.disk.inserted:info]: Disk 2b.03.11 Shelf 3 Bay 11 [NETAPP   X336_TTCRE04TA07 NA04] S/N [XXXXXXXXXXXX] UID [5000039A:C8594978:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the system
[?] Thu Apr 21 15:54:50 +0900 [node-1: config_thread: raid.rg.spares.low:error]: /dk0000_vp3nas15_aggr1/plex0/rg0
[?] Thu Apr 21 15:54:50 +0900 [node-1: config_thread: raid.rg.spares.low:error]: /dk0000_vp3nas15_aggr1/plex0/rg1
[?] Thu Apr 21 15:54:50 +0900 [node-1: config_thread: raid.rg.spares.low:error]: /dk0000_vp3nas15_aggr0/plex0/rg0
[?] Thu Apr 21 15:54:50 +0900 [node-1: config_thread: callhome.spares.low:error]: Call home for SPARES_LOW

  • 输出"sysconfig -r"可确认有足够的备用磁盘。

Pool0 spare disks

RAID Disk Device   HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
--------- ------   ------------- ---- ---- ---- ----- --------------   --------------
Spare disks for block checksum
spare   0a.00.10 0a   0   10  SA:A   0   SSD   N/A 915465/1874872832 915715/1875385008 (fast zeroed)
spare   0a.00.11 0a   0   11  SA:A   0   SSD   N/A 915465/1874872832 915715/1875385008 (fast zeroed)
spare   0a.01.10 0a   1   10  SA:A   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
spare   0a.01.11 0a   1   11  SA:A   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
spare   2b.02.10 2b   2   10  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
spare   2b.02.11 2b   2   11  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
spare   2b.03.10 2b   3   10  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)
spare   2b.03.11 2b   3   11  SA:B   0  FSAS  7200 3807816/7798408704 3815447/7814037168 (fast zeroed)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.