磁盘架中单个驱动器的持续文件系统磁盘缺失警告
适用场景
- AFF-C190
- ONTAP 9
问题描述
- 单个驱动器仍丢失
- EMS日志会显示不断插入和删除的驱动器
Sun Mar 26 00:36:05 -0400 [node-01: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0b.00.19 invalidated.', 'adapterName': '0a'}
Sun Mar 26 00:36:05 -0400 [node-01: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Invalidating device 0b.00.19. ', 'adapterName': '0a'}
Sun Mar 26 00:45:00 -0400 [node-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0b.00.19 invalidate debounce - 10', 'adapterName': '0a'}
Sun Mar 26 00:45:10 -0400 [node-01: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0b.00.19 invalidated.', 'adapterName': '0a'}
Sun Mar 26 00:45:10 -0400 [node-01: pmcsas_timeout_0: sas.adapter.debug:info]: params: {'debug_string': 'Invalidating device 0b.00.19. ', 'adapterName': '0a'}
Thu Mar 30 08:58:11 -0400 [node-01: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk 0b.00.19 Shelf 0 Bay 19 [NETAPP X371_S164A960ATE NA53] S/N [XXXXXXXXXXXX] UID [5002538B:02396360:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is missing.
Thu Mar 30 08:58:51 -0400 [node-01: config_failed_disk: callhome.fdsk.missing:error]: Call home for FILESYSTEM DISK MISSING
Thu Mar 30 09:34:16 -0400 [node-01: dmgr_thread: raid.disk.inserted:info]: Disk 0b.00.19 Shelf 0 Bay 19 [NETAPP X371_S164A960ATE NA53] S/N [XXXXXXXXXXXX] UID [5002538B:02396360:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] has been inserted into the systemSun Mar 26 00:35:55 -0400 [node-01: pmcsas_asyncd_0: sas.adapter.debug:info]: params: {'debug_string': 'Device 0b.00.19 invalidate debounce - 10', 'adapterName': '0a'}
- 重新拔插和更换驱动器无法解决问题描述 问题