节点重新启动后、数据端口物理链路指示灯亮起、ONTAP中的端口处于关闭状态
适用场景
- AF-A300/FAS-8200
- 数据端口
- 1G/10G以太网控制器CNA EP 8324
问题描述
- 重新启动后、数据端口无法联机。受影响的端口显示"Physical Link"(物理链路)指示灯、但该端口显示"Operational Link DownSYSC"(操作链路下载)。-A输出显示端口脱机、并且SFP已被识别
slot 0: 1G/10G Ethernet Controller CNA EP 8324 (Multiple Dual-port, QLogic CNA 8324(8362) rev. 2)
e0f MAC Address: ww:ww:ww:ww:ww:ww (auto-unknown-fd-down)
e0e MAC Address: xx:xx:xx:xx:xx:xx (auto-10g_sr-fd-up)
e0h MAC Address: yy:yy:yy:yy:yy:yy (auto-unknown-fd-down)
e0g MAC Address: zz:zz:zz:zz:zz:zz (auto-unknown-fd-down)
slot 0: Fibre Channel Target Host Adapter 0g
(QLogic CNA 8324 (8362) rev. 2, <LINK NOT CONNECTED>)
Firmware rev: 8.9.0
Flash rev: 5.0.2
Host Port Addr: 000000
FC Nodename: xx:xx:xx:xx:xx:xx:xx:xx (xxxxxxxxxxxxxxxx)
FC Portname: xx:xx:xx:xx:xx:xx:xx:xx (xxxxxxxxxxxxxxxx)
Connection: No link
Switch Port: Unknown
SFP Vendor Name: AVAGO
SFP Vendor P/N: AFBR-709SMZ-NA3
SFP Vendor Rev: G4.1
SFP Serial No.: AA123456XYZ
SFP Connector: LC
SFP Capabilities: 10 Gbit/Sec
- 节点SFP已通过测试、可在其他端口上正常工作:
Fri Mar 22 10:37:01 -0400 [node-02: fct_tpd_work_thread_0: scsitarget.fcp.sfp.removed:info]: An SFP was removed from FC target adapter 0g.
Fri Mar 22 10:37:31 -0400 [node-02: fct_tpd_work_thread_0: scsitarget.fcp.sfp.inserted:info]: An SFP was inserted into FC target adapter 0h.
Fri Mar 22 10:37:32 -0400 [node-02: intr: netif.linkUp:info]: Ethernet e0h: Link up.
Fri Mar 22 10:37:32 -0400 [node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node node-02, port e0h.
- 已在节点和交换机上执行SFP和缆线重新拔插、未进行任何更改
- 已更换交换机SFP并测试其工作正常
- 受影响端口的管理状态已关闭和打开、未发生更改