ifstat输出中的vifmgr.cluscheck.crcerrors警报报告长帧
- Views:
- 58
- Visibility:
- Public
- Votes:
- 0
- Category:
- ontap-9
- Specialty:
- hw<a>MTU不匹配</a><a>巨型帧</a><a>长度错误</a>
- Last Updated:
适用场景
- ONTAP 9
- FAS/AFA平台
问题描述
- 在的输出中可以看到长帧
ifstat
。示例:
-- interface e1d (5 days, 13 hours, 44 minutes, 30 seconds) --
RECEIVE
Total frames: 438k | Frames/second: 1 | Total bytes: 32232k
Bytes/second: 67 | Total errors: 32047 | Errors/minute: 4
Total discards: 0 | Discards/minute: 0 | Multi/broadcast: 561k
Non-primary u/c: 0 | CRC errors: 0 | Runt frames: 0
Long frames: 32047 | Length errors: 0 | Alignment errors: 0
No buffer: 0 | Pause: 0 | Jumbo: 0
Noproto: 0 | Bus overruns: 0 | LRO segments: 0
...
- 根据ONTAP版本、可以在EMS中记录以下任一事件
[Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed CRC errors.
[Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed hardware errors, possibly CRC errors.
[Node1: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e1d on node Node1 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
- 此端口已配置MTU 1500
- 在交换机端、交换机端口未接收任何长帧、但正在传输这些帧:
switch# show interface eth0/10
Ethernet0/10 is up
RX
0 jumbo packets 0 storm suppression bytes
TX
32047 jumbo packets