跳转到主内容

ifstat输出中的vifmgr.cluscheck.crcerrors警报报告长帧

Views:
58
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw<a>MTU不匹配</a><a>巨型帧</a><a>长度错误</a>
Last Updated:

适用场景

  • ONTAP 9
  • FAS/AFA平台

问题描述

  1. 在的输出中可以看到长帧 ifstat示例

-- interface  e1d  (5 days, 13 hours, 44 minutes, 30 seconds) --
RECEIVE
 Total frames:    438k | Frames/second:     1  | Total bytes:    32232k
 Bytes/second:     67  | Total errors:   32047 | Errors/minute:     4 
 Total discards:    0  | Discards/minute:    0  | Multi/broadcast:   561k
 Non-primary u/c:    0  | CRC errors:      0  | Runt frames:      0 
 Long frames:    32047 | Length errors:     0  | Alignment errors:   0 
 No buffer:       0  | Pause:         0  | Jumbo:         0 
 Noproto:        0  | Bus overruns:     0  | LRO segments:     0 
 ...

  1. 根据ONTAP版本、可以在EMS中记录以下任一事件
    • [Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed CRC errors.
    • [Node1: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e1d on node Node1 is reporting a high number of observed hardware errors, possibly CRC errors.
    • [Node1: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e1d on node Node1 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped).
  2. 此端口已配置MTU 1500
  3. 在交换机端、交换机端口未接收任何长帧、但正在传输这些帧:

switch# show interface eth0/10
Ethernet0/10 is up
  RX
   0 jumbo packets  0 storm suppression bytes
 TX
  32047 jumbo packets

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.