跳转到主内容

在集群网络端口上检测到 vifmgr.clus.linkdown ,而更换 SFP 不会修复问题描述

Views:
40
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9.x
  • FAS 系统
  • AFF 系统

问题描述

  • vifmgr.clus.linkdown 在事件日志中报告集群网络端口:
示例:
[node-02: ixgbe/e0b: snmp.link.down:info]: Interface 2 is down.
[node-02: ixgbe/e0b: netif.linkDown:info]: Ethernet e0b: Link down, check cable.
[node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node node-02, port e0b.
[node-02: vifmgr: vifmgr.clus.linkdown:EMERGENCY]: The cluster port e0b on node node-02 has gone down unexpectedly.
  • 即使更换了 FAS 端和集群网络交换机端的 SFP ,网络端口也会关闭。
  • FAS 端新 SFP 的序列号会正确显示在的输出 sysconfig -a中。
  • 网络缆线未出现故障。
  • 如果将缆线连接到交换机的另一个端口,则网络端口链路将会启动。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.