scsi.cmd.checkCondition:所有磁盘出错
适用于
问题描述
- 在 EMS log中接收以下错误
[Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'SSP_EVENT 0x34 on 0a.00.4, TAG 0x7ba4007e, INIT_TAG 0xcdb8: target reset'}
 [Node-01: pmcsas_admin_0: sas.adapter.debug:info]: params: {'adapterName': '0a', 'debug_string': 'ABORT TASK on device 0a.00.4 Tag 0x7ba4007e'}
 [Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.00.4: Check Condition: CDB 0x28:551af160:0018: Sense Data SCSI:aborted command - (0xb - 0x4b 0x4 0x0)(27).
 [Node-01: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0a.00.4: request successful after retry #1/#0: cdb 0x28:551af160:0018 (28).
- 在 SAS 适配器上看到递增的错误
Cluster:> node run -node Node-01 -command sasadmin adapter_state 0a
State for adapter channel 0a: UP
                          Invald Disprt Loss   Phy    Phy
                          DWord  Error  Sync   Reset  Change
    PHY STATE             Count  Count  Count  Prob   Count
    --------------------------------------------------------
      0 12.0 Gb/s         0      0      0      0      4
      1 12.0 Gb/s         0      0      0      0      4
      2 12.0 Gb/s         0      0      0      0      4
      3 12.0 Gb/s         41456  40043  0      0      4
- 连接磁盘架和控制器的 SAS 线缆已更换