A220/FAS2700、C190 上的 e0a/e0b 链路抖动导致接管
适用于
- AFF A300、AFF A220、AFF A150、AFF C190
- ASA A150
- FAS8200、FAS2750、FAS2720
- ONTAP 9
问题
检查集群端口状态和存储故障转移状态:
FAS2720::> storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
FAS2720-01 FAS2720-02 true Connected to FAS2720-02, Partial
giveback
FAS2720-02 FAS2720-01 - Waiting for cluster applications to
come online on the local node
Offline applications: mgmt, vldb,
vifmgr, bcomd, crs, scsi blade, clam.
2 entries were displayed.
FAS2720::> net in show
(network interface show)
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
Cluster
FAS2720-01_clus1
up/down 169.254.XX.XX/16 FAS2720-01 e0a true
FAS2720-01_clus2
up/down 169.254.XX.XX/16 FAS2720-01 e0b true
FAS2720-02_clus1
up/- 169.254.XX.XX/16 FAS2720-02 e0a true
FAS2720-02_clus2
up/- 169.254.XX.XX/16 FAS2720-02 e0b true- 在两个节点的同一节点上将 e0a 循环回 e0b。
- e0a/e0b 仍处于关闭状态的节点将是导致问题的节点