跳转到主内容

A220/FAS2700、C190 上的 e0a/e0b 链路抖动导致接管

Views:
466
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • AFF A300、AFF A220、AFF A150、AFF C190
  •  ASA A150
  • FAS8200、FAS2750、FAS2720
  • ONTAP 9

问题

检查集群端口状态和存储故障转移状态:
 
FAS2720::> storage failover show
Takeover
Node           Partner        Possible State Description
-------------- -------------- -------- -------------------------------------
FAS2720-01     FAS2720-02     true     Connected to FAS2720-02, Partial
giveback
FAS2720-02     FAS2720-01     -        Waiting for cluster applications to
come online on the local node
Offline applications: mgmt, vldb,
vifmgr, bcomd, crs, scsi blade, clam.
2 entries were displayed.

FAS2720::> net in show
(network interface show)
Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----
Cluster
FAS2720-01_clus1
up/down  169.254.XX.XX/16   FAS2720-01    e0a     true
FAS2720-01_clus2
up/down  169.254.XX.XX/16   FAS2720-01    e0b     true
FAS2720-02_clus1
up/-     169.254.XX.XX/16   FAS2720-02    e0a     true
FAS2720-02_clus2
up/-     169.254.XX.XX/16   FAS2720-02    e0b     true
  • 在两个节点的同一节点上将 e0a 循环回 e0b。
  • e0a/e0b 仍处于关闭状态的节点将是导致问题的节点

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.