跳转到主内容

磁盘架上出现“OT WARNING”、“Overtemperature warning”或“callhome.chassis.hitemp”警报。

Views:
194
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • FAS2620
  • FAS2720

问题

  • 在事件日志中,每小时报告一次机箱温度过高错误:

[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Ambient Temp is critical high (120 C).
[Node1: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.

[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Midplane 4 Temp is warning high (47 C).
[Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: Midplane 3 Temp is warning high (47 C).
[Node1: monitor: monitor.globalStatus.critical:EMERGENCY]: Chassis temperature is too high.. 
[Node1: env_mgr: callhome.chassis.hitemp:error]: Call home for CHASSIS OVER TEMPERATURE

  • 某些 传感器报告磁盘架上的温度过高:

::> system node run -node <node> -command storage show fault

Enclosure Status: non-critical
Channel: 0b
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFFG1914000066
Module Type: IOM12E

Temperature Sensors:
Element Status         Status Bytes  Status Descriptions
  1: OK                01,00,33,00   
  2: OK                01,00,39,00   
  3: OK                01,00,39,00   
  4: NONCRITICAL       03,00,44,04   OT WARNING
  5: NONCRITICAL       03,00,44,04   OT WARNING
  6: OK                01,00,3F,00  
 

  • 在环境日志中也可以看到过热警告:

::> system node run -node <node> -command environment status

Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15; with error: 4, 5
    Shelf temperatures by element:
      [1] 31 C (87 F) (ambient)  Normal temperature range
      [2] 37 C (98 F)  Normal temperature range
      [3] 37 C (98 F)  Normal temperature range
      [4] 48 C (118 F) Overtemperature warning!
      [5] 48 C (118 F) Overtemperature warning!
      [6] 43 C (109 F)  Normal temperature range

  • 来自 SP 传感器日志:

Sensor Name              State          Current    Critical     Warning     Warning    Critical
                                        Reading       Low         Low         High       High
-------------------------------------------------------------------------------------------------
Temp Low Shutdown                           UP
Temp High Shutdown                          UP
SNMP Bad Fan Count                          OK
Chassis is Under Temp                       NO
Chassis is Over Temp                      YES

Midplane 4 Temp          warnhigh          47 C        0 C         5 C        47 C        52 C     
Midplane 3 Temp          warnhigh          47 C        0 C         5 C        47 C        52 C     
Midplane 2 Temp          normal            36 C         0 C         5 C        47 C        52 C     
Midplane 1 Temp          normal            36 C         0 C         5 C        47 C        52 C     

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.