在sysconfig -a中、基板管理控制器状态显示为"未知"
适用场景
- FAS2750
- FAS2720
- ONTAP 9
- 底板管理控制器( BMC )
问题描述
- BMC状态和IP地址如
unknown
中所示sysconfig -a
。
Service Processor Status: Online
Firmware Version: 11.3P1
Mgmt MAC Address: XX:XX:XX:XX:XX:XX
Ethernet Link: unknown, full duplex, auto-neg complete
Using DHCP: no
IPv4 configuration:
IP Address: unknown
Netmask: unknown
Gateway: unknown
IPv6 configuration: Disabled
- EMS日志会定期显示以下消息。
[node-02: sp_config_1: spmgmt.driver.timeout:error]: The software driver for the Service Processor (SP) detected a problem: Unable to update SP network information at this time.
- BMC重新启动无法清除问题描述。
::> system service-processor reboot-sp -node node-2
SP-MGMT-MLOG-TXT.GZ
执行SP重新启动时、在日志中发现以下消息。
00000017.00059836 0536e043 Wed Jan 18 2023 17:51:40 +09:00 [kern_servprocd:info:4733] 0x808169600: 0: NOTICE: Servprocd::CLI: get_spcs_port : spcs port value in sp_api_service mdb is 50000
00000017.00059837 0536e0a8 Wed Jan 18 2023 17:51:50 +09:00 [kern_servprocd:info:4733] 0x808169600: 0: ERR: Servprocd::CLI: sp_get_sensor_info_worker : TTX ERROR: 7 (SSL_connect: Resource temporarily unavailable)
00000017.00059838 0536e0a8 Wed Jan 18 2023 17:51:50 +09:00 [kern_servprocd:info:4733] Thrift: Wed Jan 18 17:51:50 2023 SSL_shutdown: shutdown while in init
00000017.00059862 0536e0f7 Wed Jan 18 2023 17:51:55 +09:00 [kern_servprocd:info:4733] 0x808169600: 0: INFO: librpcpool: Promoting thread to RT
- 重新启动
servprocd
进程、但无法恢复。
::> set diag
::*> system node systemshell -node node-02 -command "sudo spmctl -s -h servprocd"
::*> system node systemshell -node node-02 -command "sudo spmctl -e -h servprocd"