由于电缆故障、X1146A端口脱机
适用场景
- AFF A400
- X1146A :双 40/100G 以太网 T62100-CR 卡
问题描述
- 使用缆线连接到交换机时,端口仍处于关闭状态
sysconfig -a
输出slot 2: Dual 40/100G Ethernet T62100-CR e2a MAC Address: 00:07:43:66:29:90 (auto-unknown-fd-down) e2b MAC Address: 00:07:43:66:29:98 (auto-unknown-fd-down) Device Type: T6 2 Firmware Version: 1.24.12.0 Part Number: 110122860D0 Hardware Revision: 0 Serial Number: PT19210369 slot 3: Dual 40/100G Ethernet T62100-CR e3a MAC Address: 00:07:43:66:29:d0 (auto-unknown-fd-down) e3b MAC Address: 00:07:43:66:29:d8 (auto-unknown-fd-down) Device Type: T6 2 Firmware Version: 1.24.12.0 Part Number: 110122860D0 Hardware Revision: 0 Serial Number: PT19210366
- 已在中正确检测到卡
sysconfig -ac
::> system node run -node NodeA -command sysconfig -ac sysconfig: slot 1 OK: X1146A: Dual 40/100G Ethernet T62100-CR sysconfig: slot 2 OK: X1146A: Dual 40/100G Ethernet T62100-CR sysconfig: slot 3 OK: X1146A: Dual 40/100G Ethernet T62100-CR sysconfig: No shelf configuration errors detected. sysconfig: There are no configuration errors.
- 环回测试用于确认端口保持脱机状态
- 使用铜缆时、这些端口会立即联机