当两个PSU都发生故障时、FAS9300是否会发生崩溃?

Views:
3
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
HW
Last Updated:

适用场景

  • FAS8300
  • FAS8700 
  • AFF A400
  • AFF C400 

问题解答

目标卷  当每个控制器同时具有两个PSU时、FAS9300不会发生崩溃。
 
  •  FAS8300/AFA400/AFC400 和 FAS4700 系统每个系统具有4个PSU

PSU直接插入PCM (每个箱2个)

PSU将为中板供电、如果发生故障、还将为配对PCM供电

  •  2+2配置

始终至少需要为2个电源供电、系统才能正常运行

断电或从任何位置卸下最多2个(共4个)电源仍会导致系统正常运行

每个PSU的电源贯穿整个系统(中板、风扇、配对PCM、本地PCM)

追加信息

其他信息文本
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.