SFP不受支持会导致节点接管
适用场景
- FAS8300
- 集群端口
问题描述
- 向两个节点添加了新的SFP
- EMS日志显示SFP不受支持
[node01: kernel: netif.sfpNotSupported:error]: The SFP+ or QSFP+ module (AVAGO AFBR-710SMZ) installed in e1d is not supported with this network interface.
[node02: kernel: netif.sfpNotSupported:error]: The SFP+ or QSFP+ module (AVAGO AFBR-710SMZ) installed in e1d is not supported with this network interface
[node02: kernel: netif.linkDown:debug]: Ethernet e2a: Link down, check cable.
[node02: kernel: netif.linkDown:debug]: Ethernet e2a: Link down, check cable.
[node02: intr: net.ifgrp.lacp.link.inactive:debug]:ifgrp a0a, port e2a has transitioned to an inactive state. The interface group is in a degraded state.
- 其余集群端口处于不正常状态(端口轻拍)
- 由于没有可用的集群链路、配对节点执行接管
CLTFLT:HA Group Notification from Node-02 (CONTROLLER TAKEOVER COMPLETE AUTOMATIC) ALERT